pipefittercalc

Pipe cutting template

A printable wrap-around template for cutting a branch to fit a header, square or at an angle, with the cut-back at every line.

Branch cutting template

A wrap-around template for cutting a branch pipe to fit a header, square or at an angle, with the cut-back at each line around the pipe.

How it is worked out

For a branch of radius r meeting a header of radius R at angle α, the cut-back at angle θ round the branch is t(θ) = (√(R² − r² sin²θ) − r cos θ cos α) ÷ sin α, measured from a common line; the template shows the largest value minus each value. Line 0 and the half-way line lie in the plane of both pipes; on an angled branch the half-way line is the long point on the acute side. The wrap length is π × branch OD. Check the printed scale with a ruler before cutting.

How to use it

Enter the outside diameters of the header and the branch, and the angle between them (90° for a square tee). The template unrolls the cut line round the branch. Print it at full size, check the scale bar with a ruler, cut it out, wrap it round the branch with the straight edge square to the pipe, and mark along the curve.

Without a printer

Divide the branch into equal lines round its circumference (16 is usual) and number them from a line in the plane of both pipes. Draw a square line round the pipe through the longest point (the line with a cut-back of 0) and measure each cut-back back from it, using the table the calculator gives. Join the marks with a flexible strip.

Example: 2 in branch on a 4 in header, square

LineRound the pipeCut-back (in)
00.0°0.000 (0)
122.5°0.046 (1/16)
245.0°0.163 (3/16)
367.5°0.286 (5/16)
490.0°0.339 (5/16)
5112.5°0.286 (5/16)
6135.0°0.163 (3/16)
7157.5°0.046 (1/16)
8180.0°0.000 (0)

The cut-back repeats in mirror image for lines 9 to 16.

Fit-up

The template is worked to the outside diameter of both pipes, which suits a set-on branch. For a set-in branch, or a thick wall, bevel and grind to fit and check the root gap all round before tacking.

These calculators do the arithmetic only. Check every measurement and cut before you make it, and follow the drawings, the code and the engineer of record for anything that carries pressure or load.