pipefittercalc

Pipe schedule chart

Outside diameter, wall and inside diameter for schedule 40 and 80 pipe, NPS 1/8 to 12, in inches and millimetres.

Pipe weight

The weight of a run of pipe, empty and full of water, from size and schedule or any outside diameter and wall.

How it is worked out

Weight = π × (OD − wall) × wall × length × density, which for carbon steel in inches is the familiar 10.69 × (OD − wall) × wall lb/ft. Water adds π ÷ 4 × ID² of water per unit length. Plain-end weights only; threads, couplings, coatings and linings change the figure.

Schedule 40 and 80 pipe dimensions

NPSDNOD in (mm)Sch 40 wall in (mm)Sch 40 ID in (mm)Sch 80 wall in (mm)Sch 80 ID in (mm)
1/860.405 (10.3)0.068 (1.7)0.269 (6.8)0.095 (2.4)0.215 (5.5)
1/480.540 (13.7)0.088 (2.2)0.364 (9.2)0.119 (3.0)0.302 (7.7)
3/8100.675 (17.1)0.091 (2.3)0.493 (12.5)0.126 (3.2)0.423 (10.7)
1/2150.840 (21.3)0.109 (2.8)0.622 (15.8)0.147 (3.7)0.546 (13.9)
3/4201.050 (26.7)0.113 (2.9)0.824 (20.9)0.154 (3.9)0.742 (18.8)
1251.315 (33.4)0.133 (3.4)1.049 (26.6)0.179 (4.5)0.957 (24.3)
1-1/4321.660 (42.2)0.140 (3.6)1.380 (35.1)0.191 (4.9)1.278 (32.5)
1-1/2401.900 (48.3)0.145 (3.7)1.610 (40.9)0.200 (5.1)1.500 (38.1)
2502.375 (60.3)0.154 (3.9)2.067 (52.5)0.218 (5.5)1.939 (49.3)
2-1/2652.875 (73.0)0.203 (5.2)2.469 (62.7)0.276 (7.0)2.323 (59.0)
3803.500 (88.9)0.216 (5.5)3.068 (77.9)0.300 (7.6)2.900 (73.7)
41004.500 (114.3)0.237 (6.0)4.026 (102.3)0.337 (8.6)3.826 (97.2)
51255.563 (141.3)0.258 (6.6)5.047 (128.2)0.375 (9.5)4.813 (122.3)
61506.625 (168.3)0.280 (7.1)6.065 (154.1)0.432 (11.0)5.761 (146.3)
82008.625 (219.1)0.322 (8.2)7.981 (202.7)0.500 (12.7)7.625 (193.7)
1025010.750 (273.1)0.365 (9.3)10.020 (254.5)0.594 (15.1)9.562 (242.9)
1230012.750 (323.8)0.406 (10.3)11.938 (303.2)0.688 (17.5)11.374 (288.9)

Dimensions are for welded and seamless steel pipe to ASME B36.10. Stainless pipe to ASME B36.19 uses the same outside diameters and, for schedule 40S and 80S, the same walls in these sizes.

Reading the chart

NPS (nominal pipe size) is a name, not a measurement. From 1/8 to 12 inch the outside diameter is fixed for each size and the schedule sets the wall: a higher schedule means a thicker wall and a smaller bore. From 14 inch up, the outside diameter equals the nominal size. DN is the metric name for the same size, so NPS 2 is DN 50.

Weight of a run

The calculator above fills in the OD and wall for the size and schedule you pick, and gives the weight empty and full of water for any material.

Which schedule

Schedule 40 is the same as standard weight (STD) up to 10 inch; at 12 inch, STD is 0.375 in against schedule 40's 0.406 in. Schedule 80 is the same as extra strong (XS) up to 8 inch; at 10 and 12 inch, XS is 0.500 in, thinner than schedule 80. The pressure a pipe can carry depends on its material, temperature, joints and the piping code, so take the rating from the code and the engineer of record, not from the wall alone.

These calculators do the arithmetic only. Check every measurement and cut before you make it, and follow the drawings, the code and the engineer of record for anything that carries pressure or load.