pipefittercalc

555 timer calculator

Frequency, period and duty cycle of a 555 astable oscillator, and the monostable pulse length.

555 timer

Frequency, period and duty cycle of a 555 in astable mode, and the pulse length in monostable mode.

How it is worked out

In astable mode the capacitor charges through R1 + R2 and discharges through R2 between one third and two thirds of the supply, so the output is high for ln 2 × (R1 + R2) × C = 0.693 (R1 + R2) C and low for 0.693 × R2 × C. Frequency = 1.44 ÷ ((R1 + 2 R2) × C), and the duty cycle is always above 50% unless a diode bypasses R2. In monostable mode one pulse lasts 1.1 × R × C, shown here for R1 and C.

How to use it

Enter R1 (between Vcc and pin 7), R2 (between pin 7 and pins 6 and 2) and the timing capacitor C, typing values as 1k, 10k, 10u or 100n. The calculator gives the frequency, the high and low times and the duty cycle, and the pulse length if the same R1 and C were wired as a monostable.

The formulas

High time = 0.693 × (R1 + R2) × C. Low time = 0.693 × R2 × C. Frequency = 1.44 ÷ ((R1 + 2 R2) × C). Duty cycle = (R1 + R2) ÷ (R1 + 2 R2). Monostable pulse = 1.1 × R × C.

Common values

R1R2CFrequencyDuty cycle
1 kΩ10 kΩ10 µF6.87 Hz52.4%
1 kΩ47 kΩ10 µF1.52 Hz50.5%
10 kΩ100 kΩ10 µF0.69 Hz52.4%
1 kΩ6.8 kΩ100 nF988.15 Hz53.4%
1 kΩ10 kΩ10 nF6.87 kHz52.4%
1 kΩ1 kΩ1 nF480.90 kHz66.7%

Keep R1 at 1 kΩ or more so the discharge transistor is not overloaded, and use a film capacitor for steady timing; electrolytics drift with temperature and age.

These calculators do the arithmetic only. Check every measurement and cut before you make it, and follow the drawings, the code and the engineer of record for anything that carries pressure or load.