pipefittercalc

Gas pipe sizing chart

Natural gas capacity of Schedule 40 steel pipe by size and length, and the pipe size for each section of a low-pressure system.

Natural gas pipe size

The Schedule 40 steel pipe size for one section of a low-pressure natural gas system, by the code's longest length method.

How it is worked out

The load is turned into gas flow: cubic feet per hour = Btu/h ÷ the heating value (about 1,000 for natural gas). The longest length method (IFGC 402.4.1) reads every section from one row of the table: the row for the length from the meter to the farthest outlet, rounded up. The section's size is the smallest pipe whose capacity in that row is at least the flow through it. The table is IFGC Table 402.4(2), the same as IRC Table G2413.4(1): Schedule 40 metallic pipe, natural gas, inlet pressure less than 2 psi, pressure drop 0.5 in. w.c., specific gravity 0.60.

How to use it

Add up the input ratings (Btu/h, on each appliance's rating plate) of every appliance the section of pipe feeds. Measure the length of pipe from the meter outlet to the farthest appliance, and use that one length for every section. Enter both: the calculator turns the load into cubic feet per hour and picks the smallest pipe in the table that carries it. Repeat for each section, from the meter out, each time with the load of only the appliances downstream of it.

Gas pipe sizing chart (CFH)

Length (ft)1/2 in3/4 in1 in1-1/4 in1-1/2 in2 in2-1/2 in3 in
101723606781,3902,0904,0206,40011,300
201182474669571,4302,7604,4007,780
30951993747681,1502,2203,5306,250
40811703206579851,9003,0205,350
50721512845838731,6802,6804,740
60651372575287911,5202,4304,290
70601262374867281,4002,2303,950
80561172204526771,3002,0803,670
90521102074246351,2201,9503,450
100501041954006001,1601,8403,260
12544921733555321,0201,6302,890
15040831573224829281,4802,610
17537771442964438541,3602,410
20034711342754127941,2702,240
25030631192443667041,1201,980
30027571082213316381,0201,800
3502553992033055879351,650

IFGC Table 402.4(2), also IRC Table G2413.4(1): Schedule 40 metallic pipe, natural gas, inlet pressure less than 2 psi, pressure drop 0.5 in. w.c., specific gravity 0.60. Capacities are in cubic feet of gas per hour; at about 1,000 Btu per cubic foot, 1 CFH carries about 1,000 Btu/h.

A worked example

A furnace of 100,000 Btu/h and a water heater of 40,000 Btu/h, with the farthest appliance 60 ft of pipe from the meter. Every section uses the 60 ft row. The pipe from the meter to the first tee carries 140 CFH, so it needs 1 in (257 CFH; 3/4 in carries only 137). The branch to the furnace carries 100 CFH: 3/4 in. The branch to the water heater carries 40 CFH: 1/2 in.

When this table does not apply

This table is for natural gas at a standard low pressure with a 0.5 in. w.c. drop allowed. It does not cover propane, elevated pressure (2 psi and up), CSST or copper tubing, or polyethylene pipe, which each have their own tables. Some jurisdictions and gas suppliers require a smaller allowed drop, such as 0.3 in. w.c., which gives smaller capacities. Ask the inspector whether your jurisdiction wants an equivalent length added for fittings.

Gas work needs a licence and a permit

In most places, gas piping must be installed or altered by a licensed gas fitter or plumber, under a permit, and pressure-tested and inspected before it is used. This chart is for understanding and checking a design. The adopted code where you are, the local gas supplier's rules and the inspector decide what is required. If you smell gas, leave the building and call the gas supplier's emergency line from outside.

These calculators do the arithmetic only. Check every measurement and cut before you make it, and follow the drawings, the code and the engineer of record for anything that carries pressure or load.