pipefittercalc

PVC pipe size chart

Outside diameter, wall and inside diameter of schedule 40 and 80 PVC pipe, 1/8 to 12 inch, with the weight of a run.

Pipe weight

The weight of a run of pipe, empty and full of water, from size and schedule or any outside diameter and wall.

How it is worked out

Weight = π × (OD − wall) × wall × length × density, which for carbon steel in inches is the familiar 10.69 × (OD − wall) × wall lb/ft. Water adds π ÷ 4 × ID² of water per unit length. Plain-end weights only; threads, couplings, coatings and linings change the figure.

Schedule 40 and 80 PVC dimensions

SizeOD in (mm)Sch 40 wall inSch 40 ID in (mm)Sch 80 wall inSch 80 ID in (mm)
1/80.405 (10.3)0.0680.269 (6.8)0.0950.215 (5.5)
1/40.540 (13.7)0.0880.364 (9.2)0.1190.302 (7.7)
3/80.675 (17.1)0.0910.493 (12.5)0.1260.423 (10.7)
1/20.840 (21.3)0.1090.622 (15.8)0.1470.546 (13.9)
3/41.050 (26.7)0.1130.824 (20.9)0.1540.742 (18.8)
11.315 (33.4)0.1331.049 (26.6)0.1790.957 (24.3)
1-1/41.660 (42.2)0.1401.380 (35.1)0.1911.278 (32.5)
1-1/21.900 (48.3)0.1451.610 (40.9)0.2001.500 (38.1)
22.375 (60.3)0.1542.067 (52.5)0.2181.939 (49.3)
2-1/22.875 (73.0)0.2032.469 (62.7)0.2762.323 (59.0)
33.500 (88.9)0.2163.068 (77.9)0.3002.900 (73.7)
44.500 (114.3)0.2374.026 (102.3)0.3373.826 (97.2)
55.563 (141.3)0.2585.047 (128.2)0.3754.813 (122.3)
66.625 (168.3)0.2806.065 (154.1)0.4325.761 (146.3)
88.625 (219.1)0.3227.981 (202.7)0.5007.625 (193.7)
1010.750 (273.1)0.36510.020 (254.5)0.5949.562 (242.9)
1212.750 (323.8)0.40611.938 (303.2)0.68811.374 (288.9)

Schedule 40 and 80 PVC pipe to ASTM D1785 has the same outside diameters and walls as steel pipe of the same nominal size, which is why the fittings and the chart match. The calculator above is set to PVC; it gives the weight of a run empty and full of water.

Measuring PVC pipe

The nominal size is not a measurement of the pipe. Measure the outside diameter and find it in the OD column: 1.315 in is 1 in pipe, 1.660 in is 1 1/4, 1.900 in is 1 1/2. The outside stays the same between schedules so the same fittings fit; schedule 80 has a thicker wall, a smaller bore and is usually grey.

Other PVC

Thin-wall drain and sewer pipe (ASTM D2729 and D3034), SDR pressure pipe and CPVC tube (copper tube sizes) use different dimensions. Check the print line on the pipe. The pressure a pipe can carry falls as it gets warmer, so take ratings from the maker's data for your temperature.

These calculators do the arithmetic only. Check every measurement and cut before you make it, and follow the drawings, the code and the engineer of record for anything that carries pressure or load.